Compare Products

Generac Guardian 22kW WiFi-Enabled (G00704210)
Generac Guardian 22kW WiFi-Enabled (G00704210)

Specs

General Information

Manufacturer
Generac
Generac
Model
Guardian 22kW WiFi-Enabled (G00704210)
Guardian 22kW WiFi-Enabled (G00704210)
Model Code
G00704210
G00704210
Color
Bisque
Bisque

Engine

Engine Make
Generac
Generac
Starting System
12 VDC
12 VDC
Fuel Type
Liquid Propane or Natural Gas
Liquid Propane or Natural Gas
Oil Capacity
Including filter - Approx. 1.9 qt. (1.8 l)
Including filter - Approx. 1.9 qt. (1.8 l)
Compression Ratio
9.5:1
9.5:1
Alternator
Operating - 3,600 rpm
Operating - 3,600 rpm
Displacement
999 cc
999 cc
Fuel Consumption

Natural Gas (1/2 Load) - 228 cu. ft. / hr. (6.46 cu. m. / hr.)

Natural Gas (Full load) - 327 cu. ft. / hr. (9.26 cu. m. / hr.)

Liquid Propane (1/2 Load) - 92 cu. ft. / hr. (2.53 gal. / hr.) [9.57 l / hr.]

Liquid Propane (Full load) - 142 cu. ft. / hr. (3.90 gal. / hr.) [14.77 l / hr.]

Natural Gas (1/2 Load) - 228 cu. ft. / hr. (6.46 cu. m. / hr.)

Natural Gas (Full load) - 327 cu. ft. / hr. (9.26 cu. m. / hr.)

Liquid Propane (1/2 Load) - 92 cu. ft. / hr. (2.53 gal. / hr.) [9.57 l / hr.]

Liquid Propane (Full load) - 142 cu. ft. / hr. (3.90 gal. / hr.) [14.77 l / hr.]

Battery

Not included

Requirement - 12 V, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum

Not included

Requirement - 12 V, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum

Cooling
Air
Air
Engine Model
G-Force 1000 Series
G-Force 1000 Series
Engine Type
OHV, 2 cylinders
OHV, 2 cylinders

Measurements

Weight
Unit - 466 lb. (211 kg)
Unit - 466 lb. (211 kg)
Height
29 in. (73.7 cm)
29 in. (73.7 cm)
Width
25 in. (63.5 cm)
25 in. (63.5 cm)
Length
48 in. (121.9 cm)
48 in. (121.9 cm)

Operational

AC Frequency
Rated - 60 Hz
Rated - 60 Hz
Noise Level

Sound output in 67 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

Sound output in 57 dB(A) @ 23 ft. (7 m) with generator in Quiet-Test™ low-speed exercise mode*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

Sound output in 67 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

Sound output in 57 dB(A) @ 23 ft. (7 m) with generator in Quiet-Test™ low-speed exercise mode*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

DC Output

Voltage - 240

Maximum continuous load current @ 240 V (LP) - 91.7

Maximum continuous load current @ 240 V (NG) - 81.3

Rated maximum continuous power capacity (LP) - 22,000 W*

Rated maximum continuous power capacity (NG) - 19,500 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C))

Voltage - 240

Maximum continuous load current @ 240 V (LP) - 91.7

Maximum continuous load current @ 240 V (NG) - 81.3

Rated maximum continuous power capacity (LP) - 22,000 W*

Rated maximum continuous power capacity (NG) - 19,500 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C))

Instrumentation

2 line multilingual digital LCD Evolution™ controller (English / Spanish / French / Portuguese)

System status & maintenance interval LED indicators

Main line circuit breaker - 100 A

2 line multilingual digital LCD Evolution™ controller (English / Spanish / French / Portuguese)

System status & maintenance interval LED indicators

Main line circuit breaker - 100 A

Other

Warranty
5 year limited
5 year limited

Features

Connectivity

  • ABILITY TO VIEW GENERATOR STATUS: Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind.
  • ABILITY TO VIEW GENERATOR EXERCISE / RUN AND TOTAL HOURS: Review the generator's complete protection profile for exercise hours and total hours.
  • ABILITY TO VIEW GENERATOR MAINTENANCE INFORMATION: Provides maintenance information for the specific model generator when scheduled maintenance is due.
  • MONTHLY REPORT WITH PREVIOUS MONTH’S ACTIVITY: Detailed monthly reports provide historical generator information.
  • ABILITY TO VIEW GENERATOR BATTERY INFORMATION: Built in battery diagnostics displaying current state of the battery.
  • WEATHER INFORMATION: Provides detailed local ambient weather conditions for generator location.

Engine

  • GENERAC G-FORCE DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
  • “SPINY-LOK” CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • ELECTRONIC IGNITION / SPARK ADVANCE: These features combine to assure smooth, quick starting every time.
  • FULL PRESSURE LUBRICATION SYSTEM: Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Evolution™ Controls

  • AUTO / MANUAL / OFF ILLUMINATED BUTTONS: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
  • TWO-LINE MULTILINGUAL LCD: Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
  • SEALED, RAISED BUTTONS: Smooth, weather-resistant user interface for programming and operations.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
  • GENERATOR VOLTAGE SENSING: Constantly monitors generator voltage to verify the cleanest power delivered to the home.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
  • ENGINE WARM-UP: Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • PROGRAMMABLE EXERCISE: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • SMART BATTERY CHARGER: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
  • MAIN LINE CIRCUIT BREAKER: Protects generator from overload.
  • ELECTRONIC GOVERNOR: Maintains constant 60 Hz frequency.

Features

  • TRUE POWER™ TECHNOLOGY: Delivers utility-grade power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • GENERAC'S G-FORCE™ ENGINE: is a purpose-built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that’s more reliable and requires less routine maintenance than any competitive engine.
  • QUIET-TEST™ SELF-TEST MODE: Runs at a lower RPM for a five or twelve minute test, making generators significantly quieter than other brands while consuming less fuel.
  • TOUGH, DURABLE ALL-ALUMINUM ENCLOSURE: With RhinoCoat™ powder-coated finish helps make corrosion-resistant aluminum perfect for all weather conditions.
  • SMART, USER-FRIENDLY CONTROLS: Generac’s Evolution™ Controller features a multilingual LCD display that allows users to monitor battery status and track maintenance intervals to ensure your generator is always in top operating condition.
  • MOBILE LINK™ WI-FI CONNECTIVITY FREE WITH EVERY GUARDIAN SERIES HOME STANDBY GENERATOR: Allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information, such as the current operating status and the generator’s maintenance schedule. Connect your account to your authorized service dealer for fast, friendly and convenient assistance. With Mobile Link you are taken care of before the new power outage.
  • ALEXA SMART HOME COMPATIBLE: Alexa and Mobile Link make checking your generator status even easier! Simply connect your generator to Wi-Fi, add the Mobile Link skill to your Amazon Alexa app and say, “Alexa, ask Mobile Link if I’m ready for a power outage.”
  • 5 Year Limited Warranty for automatic standby generators.
  • Generac generators and engines are engineered and assembled in the USA*. *Assembled in the USA using domestic and foreign parts
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Our RhinoCoat™ powder-coated finish helps make corrosion-resistant aluminum perfect for all weather conditions.
  • INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac’s success in providing the most reliable generators possible. Generac’s G-Force engine lineup offers added peace of mind and reliability for when it’s needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.
  • TRUE POWERTM ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • TEST CRITERIA: Prototype tested. Nema mg1-22 evaluation. System torsional tested. Motor starting ability
  • MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage.
  • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXI-MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
  • SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility.
  • Phase - 1
  • Number of rotor poles - 2
  • Power factor - 1.0
  • Exercise duration - 5 min
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Governor system - Electronic
  • Two-line plain text multilingual LCD - Simple user interface for ease of operation.
  • Auto mode button - Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser.
  • Manual mode button - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Off mode button - Stops unit. Power is removed. Control and charger still operate.
  • Utility Voltage Loss / Return to Utility adjustable (brownout setting) - From 140-171 V / 190-216 V
  • Run / Alarm / Maintenance logs - 50 events each
  • Engine start sequence - Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • Ready to Run/Maintenance messages, Engine run hours indication, Future Set Capable Exerciser/Exercise Set Error warning, Smart Battery Charger, Charger Fault/Missing AC warning, Low Battery/Battery Problem Protection and Battery Condition indication, Automatic Voltage Regulation with Over and Under Voltage Protection, Under-Frequency/Overload/Stepper Overcurrent Protection, Safety Fused/Fuse Problem Protection, Automatic Low Oil Pressure/High Oil Temperature Shutdown, Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown, High Engine Temperature Shutdown, Internal Fault/Incorrect Wiring protection, Common external fault capability and Field upgradable firmware

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulating output voltage to ±1% prevents damaging voltage spikes.
  • EPA CERTIFIED FOR NON-EMERGENCY APPLICATIONS: Allows unit to be used for demand response applications (excluding 20 kW units).
  • UL 2200 LISTED: For your safety.

Installation System

  • 14 IN. (35.6 CM) FLEXIBLE FUEL LINE CONNECTOR: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
  • INTEGRAL SEDIMENT TRAP: Meets IFGC and NFPA 54 installation requirements.

Transfer Switch

  • FULLY AUTOMATIC: Transfers vital electrical loads to the energized source of power.
  • NEMA 3R: Can be installed inside or outside for maximum flexibility.
  • INTEGRATED LOAD MANAGEMENT TECHNOLOGY: Capability to manage additional loads for efficient power management.
  • REMOTE MOUNTING: Mounts near an existing distribution panel for simple, low-cost installation.

Unit

  • SAE WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.

Connectivity

  • ABILITY TO VIEW GENERATOR STATUS: Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind.
  • ABILITY TO VIEW GENERATOR EXERCISE / RUN AND TOTAL HOURS: Review the generator's complete protection profile for exercise hours and total hours.
  • ABILITY TO VIEW GENERATOR MAINTENANCE INFORMATION: Provides maintenance information for the specific model generator when scheduled maintenance is due.
  • MONTHLY REPORT WITH PREVIOUS MONTH’S ACTIVITY: Detailed monthly reports provide historical generator information.
  • ABILITY TO VIEW GENERATOR BATTERY INFORMATION: Built in battery diagnostics displaying current state of the battery.
  • WEATHER INFORMATION: Provides detailed local ambient weather conditions for generator location.

Engine

  • GENERAC G-FORCE DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
  • “SPINY-LOK” CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • ELECTRONIC IGNITION / SPARK ADVANCE: These features combine to assure smooth, quick starting every time.
  • FULL PRESSURE LUBRICATION SYSTEM: Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Evolution™ Controls

  • AUTO / MANUAL / OFF ILLUMINATED BUTTONS: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
  • TWO-LINE MULTILINGUAL LCD: Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
  • SEALED, RAISED BUTTONS: Smooth, weather-resistant user interface for programming and operations.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
  • GENERATOR VOLTAGE SENSING: Constantly monitors generator voltage to verify the cleanest power delivered to the home.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
  • ENGINE WARM-UP: Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • PROGRAMMABLE EXERCISE: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • SMART BATTERY CHARGER: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
  • MAIN LINE CIRCUIT BREAKER: Protects generator from overload.
  • ELECTRONIC GOVERNOR: Maintains constant 60 Hz frequency.

Features

  • TRUE POWER™ TECHNOLOGY: Delivers utility-grade power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • GENERAC'S G-FORCE™ ENGINE: is a purpose-built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that’s more reliable and requires less routine maintenance than any competitive engine.
  • QUIET-TEST™ SELF-TEST MODE: Runs at a lower RPM for a five or twelve minute test, making generators significantly quieter than other brands while consuming less fuel.
  • TOUGH, DURABLE ALL-ALUMINUM ENCLOSURE: With RhinoCoat™ powder-coated finish helps make corrosion-resistant aluminum perfect for all weather conditions.
  • SMART, USER-FRIENDLY CONTROLS: Generac’s Evolution™ Controller features a multilingual LCD display that allows users to monitor battery status and track maintenance intervals to ensure your generator is always in top operating condition.
  • MOBILE LINK™ WI-FI CONNECTIVITY FREE WITH EVERY GUARDIAN SERIES HOME STANDBY GENERATOR: Allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information, such as the current operating status and the generator’s maintenance schedule. Connect your account to your authorized service dealer for fast, friendly and convenient assistance. With Mobile Link you are taken care of before the new power outage.
  • ALEXA SMART HOME COMPATIBLE: Alexa and Mobile Link make checking your generator status even easier! Simply connect your generator to Wi-Fi, add the Mobile Link skill to your Amazon Alexa app and say, “Alexa, ask Mobile Link if I’m ready for a power outage.”
  • 5 Year Limited Warranty for automatic standby generators.
  • Generac generators and engines are engineered and assembled in the USA*. *Assembled in the USA using domestic and foreign parts
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Our RhinoCoat™ powder-coated finish helps make corrosion-resistant aluminum perfect for all weather conditions.
  • INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac’s success in providing the most reliable generators possible. Generac’s G-Force engine lineup offers added peace of mind and reliability for when it’s needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.
  • TRUE POWERTM ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • TEST CRITERIA: Prototype tested. Nema mg1-22 evaluation. System torsional tested. Motor starting ability
  • MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage.
  • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXI-MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
  • SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility.
  • Phase - 1
  • Number of rotor poles - 2
  • Power factor - 1.0
  • Exercise duration - 5 min
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Governor system - Electronic
  • Two-line plain text multilingual LCD - Simple user interface for ease of operation.
  • Auto mode button - Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser.
  • Manual mode button - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Off mode button - Stops unit. Power is removed. Control and charger still operate.
  • Utility Voltage Loss / Return to Utility adjustable (brownout setting) - From 140-171 V / 190-216 V
  • Run / Alarm / Maintenance logs - 50 events each
  • Engine start sequence - Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • Ready to Run/Maintenance messages, Engine run hours indication, Future Set Capable Exerciser/Exercise Set Error warning, Smart Battery Charger, Charger Fault/Missing AC warning, Low Battery/Battery Problem Protection and Battery Condition indication, Automatic Voltage Regulation with Over and Under Voltage Protection, Under-Frequency/Overload/Stepper Overcurrent Protection, Safety Fused/Fuse Problem Protection, Automatic Low Oil Pressure/High Oil Temperature Shutdown, Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown, High Engine Temperature Shutdown, Internal Fault/Incorrect Wiring protection, Common external fault capability and Field upgradable firmware

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulating output voltage to ±1% prevents damaging voltage spikes.
  • EPA CERTIFIED FOR NON-EMERGENCY APPLICATIONS: Allows unit to be used for demand response applications (excluding 20 kW units).
  • UL 2200 LISTED: For your safety.

Installation System

  • 14 IN. (35.6 CM) FLEXIBLE FUEL LINE CONNECTOR: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
  • INTEGRAL SEDIMENT TRAP: Meets IFGC and NFPA 54 installation requirements.

Transfer Switch

  • FULLY AUTOMATIC: Transfers vital electrical loads to the energized source of power.
  • NEMA 3R: Can be installed inside or outside for maximum flexibility.
  • INTEGRATED LOAD MANAGEMENT TECHNOLOGY: Capability to manage additional loads for efficient power management.
  • REMOTE MOUNTING: Mounts near an existing distribution panel for simple, low-cost installation.

Unit

  • SAE WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.