Generac Guardian 3-Phase 20kW Automatic Standby Generator WiFi Enabled
Generac Guardian 3-Phase 20kW Automatic Standby Generator WiFi Enabled

Specs

General Information

Manufacturer
Generac
Generac
Model
Guardian 3-Phase 20kW Automatic Standby Generator WiFi Enabled
Guardian 3-Phase 20kW Automatic Standby Generator WiFi Enabled
Model Code
G0070770
G0070770
Color
Bisque
Bisque

Engine

Engine Make
Generac
Generac
Starting System
12 VDC
12 VDC
Fuel Type
Liquid Propane or Natural Gas
Liquid Propane or Natural Gas
Oil Capacity
Including filter - Approx. 1.9 qt. (1.8 l)
Including filter - Approx. 1.9 qt. (1.8 l)
Compression Ratio
9.5:1
9.5:1
Alternator
Operating - 3,600 rpm
Operating - 3,600 rpm
Displacement
999 cc
999 cc
Fuel Consumption

Natural Gas (1/2 load) - 219 cu. ft. / hr. (6.20 cu. m. / hr.)

Natural Gas (Full load) - 307 cu. ft. / hr. (8.69 cu. m. / hr.)

Liquid Propane (1/2 load) - 87 cu. ft. / hr. (2.39 gal. / hr.) [9.03 l / hr.]

Liquid Propane (Full load) - 130 cu. ft. / hr. (3.56 gal. / hr.) [13.48 l / hr.]

Natural Gas (1/2 load) - 219 cu. ft. / hr. (6.20 cu. m. / hr.)

Natural Gas (Full load) - 307 cu. ft. / hr. (8.69 cu. m. / hr.)

Liquid Propane (1/2 load) - 87 cu. ft. / hr. (2.39 gal. / hr.) [9.03 l / hr.]

Liquid Propane (Full load) - 130 cu. ft. / hr. (3.56 gal. / hr.) [13.48 l / hr.]

Battery

Not included

Requirement - 12V, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum

Not included

Requirement - 12V, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum

Cooling
Air
Air
Engine Model
G-Force 1000 Series
G-Force 1000 Series
Engine Type
OHV, 2 cylinders
OHV, 2 cylinders

Measurements

Weight
Unit - 466 lb. (211 kg)
Unit - 466 lb. (211 kg)
Height
29 in. (732 mm)
29 in. (732 mm)
Width
25 in. (638 mm)
25 in. (638 mm)
Length
48 in. (1,218 mm)
48 in. (1,218 mm)

Operational

AC Frequency
Rated - 60 Hz
Rated - 60 Hz
Noise Level

Sound output in 67 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

Sound output in 58 dB(A) @ 23 ft. (7 m) with generator in Quiet-Test™ low-speed exercise mode*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

Sound output in 67 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

Sound output in 58 dB(A) @ 23 ft. (7 m) with generator in Quiet-Test™ low-speed exercise mode*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

DC Output

Voltage - 208

Maximum continuous load current @ 208 V (LP) - 69.4

Maximum continuous load current @ 208 V (NG) - 59.0

Rated maximum continuous power capacity (LP) - 20,000 W*

Rated maximum continuous power capacity (NG) - 17,000 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F))

Voltage - 208

Maximum continuous load current @ 208 V (LP) - 69.4

Maximum continuous load current @ 208 V (NG) - 59.0

Rated maximum continuous power capacity (LP) - 20,000 W*

Rated maximum continuous power capacity (NG) - 17,000 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F))

Instrumentation

2 line LCD multilingual digital Evolution™ controller (English / Spanish / French / Portuguese)

System status & maintenance interval LED indicators

Main line circuit breaker - 80 A

2 line LCD multilingual digital Evolution™ controller (English / Spanish / French / Portuguese)

System status & maintenance interval LED indicators

Main line circuit breaker - 80 A

Other

Warranty
5 year limited
5 year limited

Features

Engine

  • GENERAC G-FORCE DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
  • QUIET-TEST™: Greatly reduces sound output and fuel consumption during bi-weekly exercise.
  • “SPINY-LOK” CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • ELECTRONIC IGNITION / SPARK ADVANCE: These features combine to assure smooth, quick starting every time.
  • FULL PRESSURE LUBRICATION SYSTEM: Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year / 200 hour oil change interval.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Evolution™ Controls

  • TWO-LINE LCD MULTILINGUAL DISPLAY: Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
  • AUTO / MANUAL / OFF ILLUMINATED BUTTONS: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
  • SEALED, RAISED BUTTONS: Smooth, weather-resistant user interface for programming and operations.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, defaults 132 V dropout, 175 V pick up.
  • GENERATOR VOLTAGE SENSING: Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
  • ENGINE WARM-UP: Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • PROGRAMMABLE EXERCISE: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • SMART BATTERY CHARGER: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
  • ELECTRONIC GOVERNOR: Maintains constant 60 Hz frequency.

Features

  • Mobile Link™ Remote Monitoring FREE with every Guardian Series Home standby generator allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information, such as the current operating status and maintenance alerts.
  • 5 Year Limited Warranty for automatic standby generators.
  • True Power™ Technology delivers best-in-class power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • Generac generators and engines are engineered and built in the USA*. *Assembled in the USA using domestic and foreign parts
  • Generac's G-Force Engine are purpose built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that's more reliable and requires less routine maintenance than any other competitor.
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Durable powder-coat finish helps make the sturdy, galvanneal steel enclosure perfect for all weather conditions
  • Smart, User-Friendly Controls Generac’s Evolution™ Controller features a dual-line, multilingual LCD display allowing for easy monitoring of history, maintenance logs making it easier to manage your generator.
  • INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING: are at the heart of Generac’s success in providing the most reliable generators possible. Generac’s G-Force™ engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.
  • TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • TEST CRITERIA: Prototype tested, System torsional tested, NEMA MG1-22 evaluation, Motor starting ability.
  • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
  • SINGLE SOURCE SERVICE RESPONSE: From Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
  • Total Harmonic Distortion: Less than 5%
  • Phase - 3
  • Number of rotor poles - 2
  • Power factor - 0.8
  • Exercise duration - 5 min
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Two-line plain text multilingual LCD display: Simple user interface for ease of operation.
  • Auto mode button - Automatic start on utility failure. 7 day exerciser.
  • Manual mode button - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Off mode button - Stops unit. Power is removed. Control and charger still operate.
  • Programmable start delay between 2–1500 seconds - Standard (programmable by dealer only)
  • Utility voltage loss / return to utility adjustable (brownout setting) - From 121-148 V / 175-187 V
  • Run / alarm / maintenance logs - 50 events each
  • Engine start sequence - Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • Ready to run/maintenance messages, Engine run hours indication, Future set capable exerciser/exercise set error warning, Smart battery charger, Charger fault/missing AC warning, Low battery/battery problem protection and battery condition indication, Automatic voltage regulation with over and under voltage Protection, Under-frequency/overload/stepper overcurrent protection, Safety fused/fuse problem protection, Automatic low oil pressure/high oil temperature shutdown, Overcrank/overspeed (@ 72 Hz)/RPM sense loss shutdown, High engine temperature shutdown, Internal fault/incorrect wiring protection, Common external fault capability, Field upgradable firmware
  • Capability to be installed within 18 in. (457 mm) of a building*. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulates the output voltage to ±1% prevents damaging voltage spikes.
  • UL 2200 LISTED: For your safety.

Installation System

  • 1 FT. (305 MM) FLEXIBLE FUEL LINE CONNECTOR: Absorbs any generator vibration when connected to rigid pipe.
  • DIRECT-TO-DIRT COMPOSITE MOUNTING PAD: Complex lattice design prevents settling or sinking of the generator system.
  • INTEGRAL SEDIMENT TRAP: Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.

Unit

  • SAE WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18" away from a building.

Engine

  • GENERAC G-FORCE DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
  • QUIET-TEST™: Greatly reduces sound output and fuel consumption during bi-weekly exercise.
  • “SPINY-LOK” CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • ELECTRONIC IGNITION / SPARK ADVANCE: These features combine to assure smooth, quick starting every time.
  • FULL PRESSURE LUBRICATION SYSTEM: Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year / 200 hour oil change interval.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Evolution™ Controls

  • TWO-LINE LCD MULTILINGUAL DISPLAY: Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
  • AUTO / MANUAL / OFF ILLUMINATED BUTTONS: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
  • SEALED, RAISED BUTTONS: Smooth, weather-resistant user interface for programming and operations.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, defaults 132 V dropout, 175 V pick up.
  • GENERATOR VOLTAGE SENSING: Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
  • ENGINE WARM-UP: Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • PROGRAMMABLE EXERCISE: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • SMART BATTERY CHARGER: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
  • ELECTRONIC GOVERNOR: Maintains constant 60 Hz frequency.

Features

  • Mobile Link™ Remote Monitoring FREE with every Guardian Series Home standby generator allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information, such as the current operating status and maintenance alerts.
  • 5 Year Limited Warranty for automatic standby generators.
  • True Power™ Technology delivers best-in-class power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • Generac generators and engines are engineered and built in the USA*. *Assembled in the USA using domestic and foreign parts
  • Generac's G-Force Engine are purpose built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that's more reliable and requires less routine maintenance than any other competitor.
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Durable powder-coat finish helps make the sturdy, galvanneal steel enclosure perfect for all weather conditions
  • Smart, User-Friendly Controls Generac’s Evolution™ Controller features a dual-line, multilingual LCD display allowing for easy monitoring of history, maintenance logs making it easier to manage your generator.
  • INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING: are at the heart of Generac’s success in providing the most reliable generators possible. Generac’s G-Force™ engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.
  • TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • TEST CRITERIA: Prototype tested, System torsional tested, NEMA MG1-22 evaluation, Motor starting ability.
  • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
  • SINGLE SOURCE SERVICE RESPONSE: From Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
  • Total Harmonic Distortion: Less than 5%
  • Phase - 3
  • Number of rotor poles - 2
  • Power factor - 0.8
  • Exercise duration - 5 min
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Two-line plain text multilingual LCD display: Simple user interface for ease of operation.
  • Auto mode button - Automatic start on utility failure. 7 day exerciser.
  • Manual mode button - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Off mode button - Stops unit. Power is removed. Control and charger still operate.
  • Programmable start delay between 2–1500 seconds - Standard (programmable by dealer only)
  • Utility voltage loss / return to utility adjustable (brownout setting) - From 121-148 V / 175-187 V
  • Run / alarm / maintenance logs - 50 events each
  • Engine start sequence - Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • Ready to run/maintenance messages, Engine run hours indication, Future set capable exerciser/exercise set error warning, Smart battery charger, Charger fault/missing AC warning, Low battery/battery problem protection and battery condition indication, Automatic voltage regulation with over and under voltage Protection, Under-frequency/overload/stepper overcurrent protection, Safety fused/fuse problem protection, Automatic low oil pressure/high oil temperature shutdown, Overcrank/overspeed (@ 72 Hz)/RPM sense loss shutdown, High engine temperature shutdown, Internal fault/incorrect wiring protection, Common external fault capability, Field upgradable firmware
  • Capability to be installed within 18 in. (457 mm) of a building*. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulates the output voltage to ±1% prevents damaging voltage spikes.
  • UL 2200 LISTED: For your safety.

Installation System

  • 1 FT. (305 MM) FLEXIBLE FUEL LINE CONNECTOR: Absorbs any generator vibration when connected to rigid pipe.
  • DIRECT-TO-DIRT COMPOSITE MOUNTING PAD: Complex lattice design prevents settling or sinking of the generator system.
  • INTEGRAL SEDIMENT TRAP: Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.

Unit

  • SAE WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18" away from a building.