Compare Products

Generac PowerPact 7.5kW with 8-circuit Transfer Switch
Generac PowerPact 7.5kW with 8-circuit Transfer Switch

Specs

General Information

Manufacturer
Generac
Generac
Model
PowerPact 7.5kW with 8-circuit Transfer Switch
PowerPact 7.5kW with 8-circuit Transfer Switch
Model Code
G0069981
G0069981
Color
Bisque
Bisque

Engine

Engine Make
Generac
Generac
Starting System
12 VDC
12 VDC
Fuel Type
Liquid Propane or Natural Gas
Liquid Propane or Natural Gas
Oil Capacity
Including filter - Approx. 1.2 qt. (1.1 l)
Including filter - Approx. 1.2 qt. (1.1 l)
Alternator
Operating - 3,600 rpm
Operating - 3,600 rpm
Displacement
420 cc
420 cc
Fuel Consumption

Natural Gas (1/2 load) - 73 cu. ft. / hr. (2.07 cu. m. / hr.)

Natural Gas (Full load) - 117 cu. ft. / hr. (33.31 cu. m. / hr.)

Liquid Propane (1/2 load) - 31.6 cu. ft. / hr. (0.87 gal. / hr.) [3.29 l / hr.]

Liquid Propane (Full load) - 51.6 cu. ft. / hr. (1.42 gal. / hr.) [5.37 l / hr.]

Natural Gas (1/2 load) - 73 cu. ft. / hr. (2.07 cu. m. / hr.)

Natural Gas (Full load) - 117 cu. ft. / hr. (33.31 cu. m. / hr.)

Liquid Propane (1/2 load) - 31.6 cu. ft. / hr. (0.87 gal. / hr.) [3.29 l / hr.]

Liquid Propane (Full load) - 51.6 cu. ft. / hr. (1.42 gal. / hr.) [5.37 l / hr.]

Battery

Not included

Requirement - Group U1, 12V and 300 CCA Minimum

Not included

Requirement - Group U1, 12V and 300 CCA Minimum

Cooling
Air
Air
Engine Model
PowerPac
PowerPac
Engine Type
OHV, 1 cylinder
OHV, 1 cylinder

Measurements

Weight
Unit - 280 lb. (127.3 kg)
Unit - 280 lb. (127.3 kg)
Height
25 in. (64 cm)
25 in. (64 cm)
Width
27 in. (67.6 cm)
27 in. (67.6 cm)
Length
36 in. (91.5 cm)
36 in. (91.5 cm)

Operational

AC Frequency
Rated - 60 Hz
Rated - 60 Hz
Noise Level

Sound output in 69 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

Sound output in 69 dB(A) @ 23 ft. (7 m) with generator operating at normal load*

(*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.)

DC Output

Voltage - 240

Maximum continuous load @ 240 V (LP) - 31.25

Maximum continuous load @ 240 V (NG) - 25

Rated maximum continuous power capacity (LP) - 7,500 W*

Rated maximum continuous power capacity (NG) - 6,000 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C))

Voltage - 240

Maximum continuous load @ 240 V (LP) - 31.25

Maximum continuous load @ 240 V (NG) - 25

Rated maximum continuous power capacity (LP) - 7,500 W*

Rated maximum continuous power capacity (NG) - 6,000 W*

(*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C))

Instrumentation

Digital LED controller

LED indicators

Main line circuit breaker - 35 A

Digital LED controller

LED indicators

Main line circuit breaker - 35 A

Other

Warranty
3 year limited
3 year limited

Features

Digital Controls

  • MULTIPLE LED ANNUNCIATION: Provides specific system information without having to open the generator enclosure.
  • AUTO / OFF / MANUAL BUTTONS: Select the operating mode.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, setpoint approximately 5 seconds.
  • ENGINE WARM-UP: Ensures engine is ready to assume the load, setpoint approximately 6 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • COLD SMART START: If the ambient temperature is cold, allows the engine to warm up before load is applied.
  • SEVEN DAY EXERCISER: Operates engine to prevent oil seal drying and damage between power outages. (Adjustable to bi-weekly or monthlythrough the Mobile Link™ system - sold separately)
  • SMART BATTERY CHARGER: Maintains battery charge level to ensure starting.
  • MAIN LINE CIRCUIT BREAKER: Protects generator from overload.
  • MULTIPLE PROTECTION FEATURES: Prevents additional damage from occurring within the generator if a fault condition arises.

Engine

  • GENERAC (OHV) DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helpsthe engine run cooler, reducing oil consumption resulting in longer engine life.
  • CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Features

  • Powers 8 circuits of your home with the 50-amp, NEMA 1 (indoor rated only) lightweight transfer switch.
  • 3 Year Limited Warranty for automatic standby generators.
  • True Power™ Technology delivers best-in-class power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • Generac generators and engines are engineered and built in the USA*. (*Assembled in the USA using domestic and foreign parts.)
  • Generac OHV engine is designed for reliability and long-life operation.
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Durable powder-coat finish helps make the sturdy, galvanneal steel enclosure perfect for all weather conditions.
  • INNOVATIVE DESIGN & PROTOTYPE TESTING: are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
  • TEST CRITERIA: Prototype tested, NEMA MG1-22 evaluation, System torsional tested, Motor starting ability.
  • POWERPACT: Offers an extreme value for those who desire automatic backup power at the most affordable price.
  • TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • SINGLE SOURCE SERVICE RESPONSE: From Generac’s extensive dealernetwork provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility.
  • Phase - 1
  • Number of rotor poles - 2
  • Power factor - 1.0
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Governor system - Mechanical
  • LED Indicators - Simple user interface for ease of operation.
  • Auto mode switch - Automatic start on utility failure. 7 day exerciser.
  • Off mode switch - Stops unit. Power is removed. Control and charger still operate.
  • Manual / test (start) - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Engine start sequence - Cyclic cranking: Engine cranks a maximum of five times at factory set intervals and durations.
  • Engine warm-up - 6 sec (30 sec with Cold Smart Start)
  • Engine cool-down - 1 min
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • 2.5 amp smart battery charger, Automatic voltage regulator, Automatic low oil level shutdown, Overspeed/Underspeed shutdown, High temperature shutdown, Overcrank protection, Safety fused, Wiring error detection, Battery problem warning, Charger problem warning, RPM sensor loss shutdown, Maintenance indicators (indicate break-in and regular maintenance is due).
  • Automatic transfer switch with built-in priority load center
  • Rated for winds up to 180 mph
  • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18 in. (457mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes.

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulates the output voltage to ±5% prevents damaging voltage spikes.
  • UL 2200 LISTED: For your safety.

Installation System

  • 14 IN (35.6 CM) FLEXIBLE FUEL LINE CONNECTOR: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.

Transfer Switch

  • FULLY AUTOMATIC: Transfers vital electrical loads to the energized source of power.
  • REMOTE MOUNTING: Mounts near existing distribution panel for simple, low cost installation.
  • FLUSH MOUNTABLE: Can be installed between studs like a standard electrical panel.
  • UL LISTED: For your safety.

Unit

  • UL WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosure ensures quiet operation and protection against mother nature. Three panels are removable for easy service and maintenance access.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18 in. (457 mm) away from a structure.

Digital Controls

  • MULTIPLE LED ANNUNCIATION: Provides specific system information without having to open the generator enclosure.
  • AUTO / OFF / MANUAL BUTTONS: Select the operating mode.
  • UTILITY VOLTAGE SENSING: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
  • UTILITY INTERRUPT DELAY: Prevents nuisance start-ups of the engine, setpoint approximately 5 seconds.
  • ENGINE WARM-UP: Ensures engine is ready to assume the load, setpoint approximately 6 seconds.
  • ENGINE COOL-DOWN: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • COLD SMART START: If the ambient temperature is cold, allows the engine to warm up before load is applied.
  • SEVEN DAY EXERCISER: Operates engine to prevent oil seal drying and damage between power outages. (Adjustable to bi-weekly or monthlythrough the Mobile Link™ system - sold separately)
  • SMART BATTERY CHARGER: Maintains battery charge level to ensure starting.
  • MAIN LINE CIRCUIT BREAKER: Protects generator from overload.
  • MULTIPLE PROTECTION FEATURES: Prevents additional damage from occurring within the generator if a fault condition arises.

Engine

  • GENERAC (OHV) DESIGN: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helpsthe engine run cooler, reducing oil consumption resulting in longer engine life.
  • CAST IRON CYLINDER WALLS: Rigid construction and added durability provide long engine life.
  • LOW OIL PRESSURE SHUTDOWN SYSTEM: Shutdown protection prevents catastrophic engine damage due to low oil.
  • HIGH TEMPERATURE SHUTDOWN: Prevents damage due to overheating.

Features

  • Powers 8 circuits of your home with the 50-amp, NEMA 1 (indoor rated only) lightweight transfer switch.
  • 3 Year Limited Warranty for automatic standby generators.
  • True Power™ Technology delivers best-in-class power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
  • Generac generators and engines are engineered and built in the USA*. (*Assembled in the USA using domestic and foreign parts.)
  • Generac OHV engine is designed for reliability and long-life operation.
  • 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
  • Durable powder-coat finish helps make the sturdy, galvanneal steel enclosure perfect for all weather conditions.
  • INNOVATIVE DESIGN & PROTOTYPE TESTING: are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
  • TEST CRITERIA: Prototype tested, NEMA MG1-22 evaluation, System torsional tested, Motor starting ability.
  • POWERPACT: Offers an extreme value for those who desire automatic backup power at the most affordable price.
  • TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
  • SINGLE SOURCE SERVICE RESPONSE: From Generac’s extensive dealernetwork provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
  • GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility.
  • Phase - 1
  • Number of rotor poles - 2
  • Power factor - 1.0
  • Cylinder block - Aluminum with cast iron sleeve
  • Ignition system - Solid-state with magneto
  • Governor system - Mechanical
  • LED Indicators - Simple user interface for ease of operation.
  • Auto mode switch - Automatic start on utility failure. 7 day exerciser.
  • Off mode switch - Stops unit. Power is removed. Control and charger still operate.
  • Manual / test (start) - Start with starter control, unit stays on. If utility fails, transfer to load takes place.
  • Engine start sequence - Cyclic cranking: Engine cranks a maximum of five times at factory set intervals and durations.
  • Engine warm-up - 6 sec (30 sec with Cold Smart Start)
  • Engine cool-down - 1 min
  • Starter lock-out - Starter cannot re-engage until 5 sec after engine has stopped.
  • 2.5 amp smart battery charger, Automatic voltage regulator, Automatic low oil level shutdown, Overspeed/Underspeed shutdown, High temperature shutdown, Overcrank protection, Safety fused, Wiring error detection, Battery problem warning, Charger problem warning, RPM sensor loss shutdown, Maintenance indicators (indicate break-in and regular maintenance is due).
  • Automatic transfer switch with built-in priority load center
  • Rated for winds up to 180 mph
  • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18 in. (457mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes.

Generator

  • REVOLVING FIELD: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • SKEWED STATOR: Produces a smooth output waveform for compatibility with electronic equipment.
  • DISPLACED PHASE EXCITATION: Maximizes motor starting capability.
  • AUTOMATIC VOLTAGE REGULATION: Regulates the output voltage to ±5% prevents damaging voltage spikes.
  • UL 2200 LISTED: For your safety.

Installation System

  • 14 IN (35.6 CM) FLEXIBLE FUEL LINE CONNECTOR: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.

Transfer Switch

  • FULLY AUTOMATIC: Transfers vital electrical loads to the energized source of power.
  • REMOTE MOUNTING: Mounts near existing distribution panel for simple, low cost installation.
  • FLUSH MOUNTABLE: Can be installed between studs like a standard electrical panel.
  • UL LISTED: For your safety.

Unit

  • UL WEATHER PROTECTIVE ENCLOSURE: Sound attenuated enclosure ensures quiet operation and protection against mother nature. Three panels are removable for easy service and maintenance access.
  • ENCLOSED CRITICAL GRADE MUFFLER: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • SMALL, COMPACT, ATTRACTIVE: Makes for an easy, eye appealing installation, as close as 18 in. (457 mm) away from a structure.